rcourtman 20854256c3 Fix VM migration issue where custom alert thresholds are lost
Resolves #641

## Problem
When a VM migrates between Proxmox nodes, Pulse was treating it as a new
resource and discarding custom alert threshold overrides. This occurred
because guest IDs included the node name (e.g., `instance-node-VMID`),
causing the ID to change when the VM moved to a different node.

Users reported that after migrating a VM, previously disabled alerts
(e.g., memory threshold set to 0) would resume firing.

## Root Cause
Guest IDs were constructed as:
- Standalone: `node-VMID`
- Cluster: `instance-node-VMID`

When a VM migrated from node1 to node2, the ID changed from
`instance-node1-100` to `instance-node2-100`, causing:
- Alert threshold overrides to be orphaned (keyed by old ID)
- Guest metadata (custom URLs, descriptions) to be orphaned
- Active alerts to reference the wrong resource ID

## Solution
Changed guest ID format to be stable across node migrations:
- New format: `instance-VMID` (for both standalone and cluster)
- Retains uniqueness across instances while being node-independent
- Allows VMs to migrate freely without losing configuration

## Implementation

### Backend Changes
1. **Guest ID Construction** (`monitor_polling.go`):
   - Simplified to always use `instance-VMID` format
   - Removed node from the ID construction logic

2. **Alert Override Migration** (`alerts.go`):
   - Added lazy migration in `getGuestThresholds()`
   - Detects legacy ID formats and migrates to new format
   - Preserves user configurations automatically

3. **Guest Metadata Migration** (`guest_metadata.go`):
   - Added `GetWithLegacyMigration()` helper method
   - Called during VM/container polling to migrate metadata
   - Preserves custom URLs and descriptions

4. **Active Alerts Migration** (`alerts.go`):
   - Added migration logic in `LoadActiveAlerts()`
   - Translates legacy alert resource IDs to new format
   - Preserves alert acknowledgments across restarts

### Frontend Changes
5. **ID Construction Updates**:
   - `ThresholdsTable.tsx`: Updated fallback from `instance-node-vmid` to `instance-vmid`
   - `Dashboard.tsx`: Simplified guest ID construction
   - `GuestRow.tsx`: Updated `buildGuestId()` helper

## Migration Strategy
- **Lazy Migration**: Configs are migrated as guests are discovered
- **Backwards Compatible**: Old IDs are detected and automatically converted
- **Zero Downtime**: No manual intervention required
- **Persisted**: Migrated configs are saved on next config write cycle

## Testing Recommendations
After deployment:
1. Verify existing alert overrides still apply
2. Test VM migration - confirm thresholds persist
3. Check guest metadata (custom URLs) survive migration
4. Verify active alerts maintain acknowledgment state

## Related
- Addresses similar issues with guest metadata and active alert tracking
- Lays groundwork for any future guest-specific configuration features
- Aligns with project philosophy: correctness and UX over implementation complexity
2025-11-06 10:27:15 +00:00
..
alerts.go Fix VM migration issue where custom alert thresholds are lost 2025-11-06 10:27:15 +00:00
alerts_test.go Skip false health alerts for Samsung 980/990 SSDs and improve Docker CPU calculation 2025-11-05 19:33:16 +00:00
concurrency_test.go Fix settings security tab navigation 2025-10-11 23:29:47 +00:00
history.go perf: reduce polling allocations and guest metadata load 2025-10-25 13:12:47 +00:00
history_concurrency_test.go Fix settings security tab navigation 2025-10-11 23:29:47 +00:00
offline_toggle_test.go feat: finalize swarm service monitoring (#598) 2025-10-26 09:35:49 +00:00
per_metric_delay_example_test.go Add configurable SSH port for temperature monitoring 2025-11-05 20:03:29 +00:00
quiet_hours_test.go Fix settings security tab navigation 2025-10-11 23:29:47 +00:00
threshold_update_test.go Fix settings security tab navigation 2025-10-11 23:29:47 +00:00
time_threshold_test.go Fix settings security tab navigation 2025-10-11 23:29:47 +00:00