Commit graph

12 commits

Author SHA1 Message Date
rcourtman
b1831d7b3e Add guest URL support for PVE hosts
Related to discussion #615

Add optional GuestURL field to PVE instances and cluster endpoints,
allowing users to specify a separate guest-accessible URL for web UI
navigation that differs from the internal management URL.

Backend changes:
- Add GuestURL field to PVEInstance and ClusterEndpoint structs
- Add GuestURL field to Node model
- Update cluster auto-discovery to preserve existing GuestURL values
- Update node creation logic to populate GuestURL from config
- Update API handlers to accept and persist GuestURL field

Frontend changes:
- Add GuestURL input field to NodeModal for configuration
- Update NodeGroupHeader and NodeSummaryTable to use GuestURL for navigation
- Add GuestURL to Node and PVENodeConfig TypeScript interfaces

When GuestURL is configured, it will be used for navigation links
instead of the Host URL, allowing users to access PVE hosts through
a reverse proxy or different domain while maintaining internal API
connections.
2025-11-05 19:06:08 +00:00
rcourtman
27f2038dab Add per-node temperature monitoring and fix critical config update bug
This commit implements per-node temperature monitoring control and fixes a critical
bug where partial node updates were destroying existing configuration.

Backend changes:
- Add TemperatureMonitoringEnabled field (*bool) to PVEInstance, PBSInstance, and PMGInstance
- Update monitor.go to check per-node temperature setting with global fallback
- Convert all NodeConfigRequest boolean fields to *bool pointers
- Add nil checks in HandleUpdateNode to prevent overwriting unmodified fields
- Fix critical bug where partial updates zeroed out MonitorVMs, MonitorContainers, etc.
- Update NodeResponse, NodeFrontend, and StateSnapshot to include temperature setting
- Fix HandleAddNode and test connection handlers to use pointer-based boolean fields

Frontend changes:
- Add temperatureMonitoringEnabled to Node interface and config types
- Create per-node temperature monitoring toggle handler with optimistic updates
- Update NodeModal to wire up per-node temperature toggle
- Add isTemperatureMonitoringEnabled helper to check effective monitoring state
- Update ConfiguredNodeTables to show/hide temperature badge based on monitoring state
- Update NodeSummaryTable to conditionally show temperature column
- Pass globalTemperatureMonitoringEnabled prop through component tree

The critical bug fix ensures that when updating a single field (like temperature
monitoring), the backend only modifies that specific field instead of zeroing out
all other boolean configuration fields.
2025-11-05 14:11:53 +00:00
rcourtman
93faaacbd1 Simplify metric bar labels 2025-10-29 10:37:18 +00:00
rcourtman
f2acdd59af Normalize docker agent version handling 2025-10-28 08:42:58 +00:00
rcourtman
bc479643e4 release: prepare v4.25.0 2025-10-22 10:46:18 +00:00
rcourtman
ff4dc49ae4 Update Pulse install flow and related components 2025-10-21 19:58:53 +00:00
Pulse Automation Bot
0b4e4f9c59 Add configurable backup polling interval 2025-10-18 13:06:41 +00:00
Richard Courtman
d79b8e8883 feat: display temperature min/max range in tooltip and remove unused NodeCard
- Add instant-display tooltip on temperature column showing min-max range
- Color-code min/max temperatures individually (green/yellow/red)
- Remove unused NodeCard.tsx component from codebase
- Keep table row height consistent by using tooltip instead of inline display

🤖 Generated with [Claude Code](https://claude.com/claude-code)

Co-Authored-By: Claude <noreply@anthropic.com>
2025-10-18 08:57:10 +00:00
rcourtman
dd9bd65a2e fix: Add hasCPU/hasNVMe flags to prevent false 'no CPU sensor' errors
Addresses #101

v4.23.0 introduced a regression where systems with only NVMe temperatures
(no CPU sensor) would display "No CPU sensor" in the UI. This was caused
by the Available flag being set to true when NVMe temps existed, even
without CPU data, triggering the error message in the frontend.

Backend changes:
- Add HasCPU and HasNVMe boolean fields to Temperature model
- Extend CPU sensor detection to support more chip types: zenpower,
  k8temp, acpitz, it87 (case-insensitive matching)
- HasCPU is set based on CPU chip detection (coretemp, k10temp, etc.),
  not value thresholds
- This prevents false negatives when sensors report 0°C during resets
- CPU temperature values now accepted even when 0 (checked with !IsNaN
  instead of > 0)
- extractTempInput returns NaN instead of 0 when no data found
- Available flag means "any temperature data exists" for backward compatibility
- Update mock generator to properly set the new flags
- Add unit tests for NVMe-only and 0°C scenarios to prevent regression
- Removed amd_energy from CPU chip list (power sensor, not temperature)

Frontend changes:
- Add hasCPU and hasNVMe optional fields to Temperature interface
- Update NodeSummaryTable to check hasCPU flag with fallback to available
  for backward compatibility with older API responses
- Update NodeCard temperature display logic with same fallback pattern
- Systems with only NVMe temps now show "-" instead of error message
- Fallback ensures UI works with both old and new API responses

Testing:
- All unit tests pass including NVMe-only and 0°C test cases
- Fix prevents false "no CPU sensor" errors when sensors temporarily report 0°C
- Fix eliminates false "no CPU sensor" errors for NVMe-only systems
2025-10-13 10:17:17 +00:00
rcourtman
18a88cb4cc Improve NVMe temperature handling 2025-10-12 16:06:55 +00:00
rcourtman
274f36daa8 Improve dashboard responsiveness and temperature handling 2025-10-12 10:34:06 +00:00
rcourtman
f46ff1792b Fix settings security tab navigation 2025-10-11 23:29:47 +00:00