Test normalizeLabel, normalizeNodeLabel, splitInstanceKey,
breakerStateToValue, sanitizeInstanceLabels, makeMetricKey,
and makeNodeMetricKey with 36 test cases covering edge cases
like empty strings, whitespace, and invalid inputs.
Move the inline filesystem skip logic from pollVMsAndContainersEfficient
into a reusable ShouldSkipFilesystem function. This consolidates filtering
for virtual filesystems (tmpfs, cgroup, etc.), network mounts (nfs, cifs,
fuse), and special mountpoints (/dev, /proc, /snap, etc.) into one tested
location.
Reduces cyclomatic complexity of pollVMsAndContainersEfficient and adds
28 test cases covering virtual fs types, network mounts, special mounts,
Windows paths, and edge cases.
When api_tokens.json is modified on disk, the ConfigWatcher reloads
the tokens into memory. However, the Monitor's dockerTokenBindings and
hostTokenBindings maps were not synchronized with the new token set,
causing orphaned bindings when agents reconnect after reinstall.
Add SetAPITokenReloadCallback to ConfigWatcher that triggers Monitor's
new RebuildTokenBindings method after token reload. This method
reconstructs the binding maps from current Docker host and host agent
state, keeping only bindings for tokens that still exist in config.
Related to #773
Mark intentionally unused parameters with underscore to:
- Silence unparam warnings for legitimate unused parameters
- Keep function signatures intact for API compatibility
- Remove unused req from serveChecksum helper
- Replace custom maxInt64 helper with Go 1.21+ builtin max()
- Mark unused cfg parameter in newAdaptiveIntervalSelector
- Remove test for deleted helper function
- Merge variable declaration with assignment (S1021)
- Use unconditional strings.TrimPrefix (S1017)
- Remove unnecessary nil checks around range (S1031)
- Remove unnecessary fmt.Sprintf (S1039)
- Use copy() instead of manual loop (S1001)
- Use time.Until instead of t.Sub(time.Now()) (S1024)
- Use buf.String() instead of string(buf.Bytes()) (S1030)
- Fix SA4006 unused value issues in ssh.go, validation.go, generator.go
- Replace deprecated ioutil with io/os in config.go
- Replace deprecated tar.TypeRegA with tar.TypeReg
- Remove deprecated rand.Seed calls (auto-seeded in Go 1.20+)
- Fix always-true nil check in main.go
- Fix impossible nil comparison in tempproxy/client.go
- Add nil check for config in monitor.New()
- Use defer for tempCancel() to ensure context is always cancelled
- Remove redundant shouldCollect variable that was always true
- Fix indentation after removing the unnecessary conditional block
Add seamless migration path from legacy agents to unified agent:
- Add AgentType field to report payloads (unified vs legacy detection)
- Update server to detect legacy agents by type instead of version
- Add UI banner showing upgrade command when legacy agents are detected
- Add deprecation notice to install-host-agent.ps1
- Create install-docker-agent.sh stub that redirects to unified installer
Legacy agents (pulse-host-agent, pulse-docker-agent) now show a "Legacy"
badge in the UI with a one-click copy command to upgrade to the unified
agent.
- Implemented adaptive layout for NodeSummaryTable with responsive columns and sticky name column.
- Fixed GuestRow background display issues.
- Added IsLegacy field to Host and DockerHost models to flag legacy agents (version < 1.0.0).
- Updated monitor to populate IsLegacy based on agent version.
- Removed global legacySSHDisabled flag that was triggered by any single node auth failure
- Changed disableLegacySSHOnAuthFailure to only log warnings
- Fixed potential context leak in monitor.go
- Updated tests to reflect removal of global disable logic
Fixes#727. Previously, if temperature monitoring was enabled and a node wasn't found in ClusterEndpoints, the entire node processing was skipped. This change ensures we only skip temperature collection.
During cluster startup, nodes were temporarily using the primary cluster
endpoint for temperature collection before cluster metadata validation
completed. This caused all nodes to show the same (incorrect) temperature
values for ~4 minutes until validation finished and per-node endpoints
were established.
Example: minipc would show delly's temperature (90°C) instead of its own
(50°C) from startup until cluster validation completed.
Root cause:
- Temperature collection started immediately at startup
- Cluster endpoint validation happened asynchronously
- Code fell back to primary endpoint when ClusterEndpoints was empty
- All nodes used same endpoint, got same temperature data
Fix: Skip temperature collection for cluster nodes until:
1. ClusterEndpoints array is populated (validation complete)
2. Node's specific endpoint is found in the cluster metadata
This ensures correct temperature data from the very first collection,
maintaining data integrity during startup. When persisted config exists,
endpoints are available immediately so no delay occurs. For new clusters,
temperature collection begins once validation completes (~30s).
Preserves Pulse's correctness guarantee: users can trust metrics
immediately after restart without waiting for "warm-up" period.
## HTTP Server Fixes
- Add source IP middleware to enforce allowed_source_subnets
- Fix missing source subnet validation for external HTTP requests
- HTTP health endpoint now respects subnet restrictions
## Installer Improvements
- Auto-configure allowed_source_subnets with Pulse server IP
- Add cluster node hostnames to allowed_nodes (not just IPs)
- Fix node validation to accept both hostnames and IPs
- Add Pulse server reachability check before installation
- Add port availability check for HTTP mode
- Add automatic rollback on service startup failure
- Add HTTP endpoint health check after installation
- Fix config backup and deduplication (prevent duplicate keys)
- Fix IPv4 validation with loopback rejection
- Improve registration retry logic with detailed errors
- Add automatic LXC bind mount cleanup on uninstall
## Temperature Collection Fixes
- Add local temperature collection for self-monitoring nodes
- Fix node identifier matching (use hostname not SSH host)
- Fix JSON double-encoding in HTTP client response
Related to #XXX (temperature monitoring fixes)
This implements HTTP/HTTPS support for pulse-sensor-proxy to enable
temperature monitoring across multiple separate Proxmox instances.
Architecture changes:
- Dual-mode operation: Unix socket (local) + HTTPS (remote)
- Unix socket remains default for security/performance (no breaking change)
- HTTP mode enables temps from external PVE hosts
Backend implementation:
- Add HTTPS server with TLS + Bearer token authentication to sensor-proxy
- Add TemperatureProxyURL and TemperatureProxyToken fields to PVEInstance
- Add HTTP client (internal/tempproxy/http_client.go) for remote proxy calls
- Update temperature collector to prefer HTTP proxy when configured
- Fallback logic: HTTP proxy → Unix socket → direct SSH (if not containerized)
Configuration:
- pulse-sensor-proxy config: http_enabled, http_listen_addr, http_tls_cert/key, http_auth_token
- PVEInstance config: temperature_proxy_url, temperature_proxy_token
- Environment variables: PULSE_SENSOR_PROXY_HTTP_* for all HTTP settings
Security:
- TLS 1.2+ with modern cipher suites
- Constant-time token comparison (timing attack prevention)
- Rate limiting applied to HTTP requests (shared with socket mode)
- Audit logging for all HTTP requests
Next steps:
- Update installer script to support HTTP mode + auto-registration
- Add Pulse API endpoint for proxy registration
- Generate TLS certificates during installation
- Test multi-instance temperature collection
Related to #571 (multi-instance architecture)
Squashfs snap mounts on Ubuntu (and similar read-only filesystems like
erofs on Home Assistant OS) always report near-full usage and trigger
false disk alerts. The filter logic existed in Proxmox monitoring but
wasn't applied to host agents.
Changes:
- Extract read-only filesystem filter to shared pkg/fsfilters package
- Apply filter in hostmetrics.collectDisks() for host/docker agents
- Apply filter in monitor.ApplyHostReport() for backward compatibility
- Convert internal/monitoring/fs_filters.go to wrapper functions
This prevents squashfs, erofs, iso9660, cdfs, udf, cramfs, romfs, and
saturated overlay filesystems from generating alerts. Filtering happens
at both collection time (agents) and ingestion time (server) to ensure
older agents don't cause false alerts until they're updated.
Update test expectations to match new SMART-preferred behavior:
- mergeNVMeTempsIntoDisks now prioritizes SMART temps over NVMe temps
- NVMe temps only applied to disks with Temperature == 0
- Tests were failing because disks started with non-zero temperatures
- Changed test disks to start with Temperature: 0 to simulate fresh disks
This change was introduced in commit 2a79d57f7 (Add SMART temperature
collection for physical disks) but tests weren't updated.
Fixes TestMergeNVMeTempsIntoDisks and TestMergeNVMeTempsIntoDisksClearsMissingOrInvalid.
Two critical fixes to prevent test timeouts:
1. Nil map panic in TestPollPVEInstanceUsesRRDMemUsedFallback:
- Test monitor was missing nodeLastOnline map initialization
- Panic occurred when pollPVEInstance tried to update nodeLastOnline[nodeID]
- Caused deadlock when panic recovery tried to acquire already-held mutex
- Added nodeLastOnline: make(map[string]time.Time) to test monitor
2. Alert manager goroutine leak in Docker tests:
- newTestMonitor() created alert manager but never stopped it
- Background goroutines (escalationChecker, periodicSaveAlerts) kept running
- Added t.Cleanup(func() { m.alertManager.Stop() }) to test helper
These fixes resolve the 10+ minute test timeouts in CI workflows.
Related to workflow run 19281508603.