- Add comprehensive test coverage for alerts package with 285+ new tests
- Implement ThresholdsTable component with metric thresholds display
- Enhance Alerts page UI with improved layout and metric filtering
- Add frontend component tests for Alerts page and ThresholdsTable
- Set up Vitest testing infrastructure for SolidJS components
- Improve config persistence with better validation
- Expand discovery tests with 333+ test cases
- Update API, configuration, and Docker monitoring documentation
Addresses user concern about technical debt: detection code exists only
to handle migration from SSH-in-container to proxy architecture, not to
serve functional purpose of the application.
Changes:
- Add PULSE_LEGACY_DETECTION env var to disable detection without redeployment
- Add explicit removal criteria: v5.0 or <1% detection rate for 30+ days
- Mark all detection code with "MIGRATION SCAFFOLDING" warnings
- Create MIGRATION_SCAFFOLDING.md to track temporary code across codebase
- Document removal instructions for when migration period ends
Backend:
- internal/api/router.go: detectLegacySSH() checks env var and has removal plan
- internal/api/types.go: HealthResponse fields documented as temporary
Frontend:
- src/components/LegacySSHBanner.tsx: Component marked with removal criteria
- src/App.tsx: Banner integration (will be removed with component)
This approach balances user safety during migration (auto-detection catches
rushed admins who skip changelogs) with long-term code cleanliness (explicit
removal plan prevents indefinite technical debt).
Addresses #101
v4.23.0 introduced a regression where systems with only NVMe temperatures
(no CPU sensor) would display "No CPU sensor" in the UI. This was caused
by the Available flag being set to true when NVMe temps existed, even
without CPU data, triggering the error message in the frontend.
Backend changes:
- Add HasCPU and HasNVMe boolean fields to Temperature model
- Extend CPU sensor detection to support more chip types: zenpower,
k8temp, acpitz, it87 (case-insensitive matching)
- HasCPU is set based on CPU chip detection (coretemp, k10temp, etc.),
not value thresholds
- This prevents false negatives when sensors report 0°C during resets
- CPU temperature values now accepted even when 0 (checked with !IsNaN
instead of > 0)
- extractTempInput returns NaN instead of 0 when no data found
- Available flag means "any temperature data exists" for backward compatibility
- Update mock generator to properly set the new flags
- Add unit tests for NVMe-only and 0°C scenarios to prevent regression
- Removed amd_energy from CPU chip list (power sensor, not temperature)
Frontend changes:
- Add hasCPU and hasNVMe optional fields to Temperature interface
- Update NodeSummaryTable to check hasCPU flag with fallback to available
for backward compatibility with older API responses
- Update NodeCard temperature display logic with same fallback pattern
- Systems with only NVMe temps now show "-" instead of error message
- Fallback ensures UI works with both old and new API responses
Testing:
- All unit tests pass including NVMe-only and 0°C test cases
- Fix prevents false "no CPU sensor" errors when sensors temporarily report 0°C
- Fix eliminates false "no CPU sensor" errors for NVMe-only systems
The update progress modal was stuck showing 'initializing' even after the
backend restarted and websocket reconnected. Users could see the connection
status badge reconnecting behind the modal, but the modal never cleared.
Now the modal:
- Watches websocket connection status during update
- Detects when backend disconnects and reconnects
- Verifies health after reconnection
- Automatically reloads the page when update is complete
- Shows clearer messaging about restart progress