This commit implements per-node temperature monitoring control and fixes a critical
bug where partial node updates were destroying existing configuration.
Backend changes:
- Add TemperatureMonitoringEnabled field (*bool) to PVEInstance, PBSInstance, and PMGInstance
- Update monitor.go to check per-node temperature setting with global fallback
- Convert all NodeConfigRequest boolean fields to *bool pointers
- Add nil checks in HandleUpdateNode to prevent overwriting unmodified fields
- Fix critical bug where partial updates zeroed out MonitorVMs, MonitorContainers, etc.
- Update NodeResponse, NodeFrontend, and StateSnapshot to include temperature setting
- Fix HandleAddNode and test connection handlers to use pointer-based boolean fields
Frontend changes:
- Add temperatureMonitoringEnabled to Node interface and config types
- Create per-node temperature monitoring toggle handler with optimistic updates
- Update NodeModal to wire up per-node temperature toggle
- Add isTemperatureMonitoringEnabled helper to check effective monitoring state
- Update ConfiguredNodeTables to show/hide temperature badge based on monitoring state
- Update NodeSummaryTable to conditionally show temperature column
- Pass globalTemperatureMonitoringEnabled prop through component tree
The critical bug fix ensures that when updating a single field (like temperature
monitoring), the backend only modifies that specific field instead of zeroing out
all other boolean configuration fields.
Extends Docker container monitoring with comprehensive disk and storage information:
- Writable layer size and root filesystem usage displayed in new Disk column
- Block I/O statistics (read/write bytes totals) shown in container drawer
- Mount metadata including type, source, destination, mode, and driver details
- Configurable via --collect-disk flag (enabled by default, can be disabled for large fleets)
Also fixes config watcher to consistently use production auth config path instead of following PULSE_DATA_DIR when in mock mode.
Introduces granular permission scopes for API tokens (docker:report, docker:manage, host-agent:report, monitoring:read/write, settings:read/write) allowing tokens to be restricted to minimum required access. Legacy tokens default to full access until scopes are explicitly configured.
Adds standalone host agent for monitoring Linux, macOS, and Windows servers outside Proxmox/Docker estates. New Servers workspace in UI displays uptime, OS metadata, and capacity metrics from enrolled agents.
Includes comprehensive token management UI overhaul with scope presets, inline editing, and visual scope indicators.
Track minimum and maximum CPU temperatures since monitoring started.
This provides better insight into temperature trends and cooling
adequacy over time.
Changes:
- Backend: Add CPUMin, CPUMaxRecord, MinRecorded, MaxRecorded fields
to Temperature model
- Backend: Implement min/max tracking logic in monitoring cycle that
preserves values across polling cycles
- Backend: Initialize min/max on first reading, update on extremes
- Frontend: Update Temperature TypeScript interface with new fields
- Frontend: Display min/max range in NodeCard tooltip (e.g., "52°C
(48-67°C since monitoring started)")
- Frontend: Rebuild dist assets
Temperature display now shows:
- Current temperature with color coding (green/yellow/red)
- Tooltip with full min-max range and context
- Min/max tracked in-memory (resets on Pulse restart)
Example tooltip: "CPU: 52°C (48-67°C since monitoring started)"
🤖 Generated with [Claude Code](https://claude.com/claude-code)
Co-Authored-By: Claude <noreply@anthropic.com>
Addresses #101
v4.23.0 introduced a regression where systems with only NVMe temperatures
(no CPU sensor) would display "No CPU sensor" in the UI. This was caused
by the Available flag being set to true when NVMe temps existed, even
without CPU data, triggering the error message in the frontend.
Backend changes:
- Add HasCPU and HasNVMe boolean fields to Temperature model
- Extend CPU sensor detection to support more chip types: zenpower,
k8temp, acpitz, it87 (case-insensitive matching)
- HasCPU is set based on CPU chip detection (coretemp, k10temp, etc.),
not value thresholds
- This prevents false negatives when sensors report 0°C during resets
- CPU temperature values now accepted even when 0 (checked with !IsNaN
instead of > 0)
- extractTempInput returns NaN instead of 0 when no data found
- Available flag means "any temperature data exists" for backward compatibility
- Update mock generator to properly set the new flags
- Add unit tests for NVMe-only and 0°C scenarios to prevent regression
- Removed amd_energy from CPU chip list (power sensor, not temperature)
Frontend changes:
- Add hasCPU and hasNVMe optional fields to Temperature interface
- Update NodeSummaryTable to check hasCPU flag with fallback to available
for backward compatibility with older API responses
- Update NodeCard temperature display logic with same fallback pattern
- Systems with only NVMe temps now show "-" instead of error message
- Fallback ensures UI works with both old and new API responses
Testing:
- All unit tests pass including NVMe-only and 0°C test cases
- Fix prevents false "no CPU sensor" errors when sensors temporarily report 0°C
- Fix eliminates false "no CPU sensor" errors for NVMe-only systems